Fire Trak U.L. Listings

Construction Joints - 2004 U.L. Fire Resistance - Volume 2A Directory

The Fire Trak System has been fire tested at Underwriters Laboratories in accordance with U.L. 2079 and ASTM E 1966 test standards. The test assemblies were cycled 500 times, 100 cycles at 30 CPM and 400 cycles at 10 CPM. The assemblies have movement capabilities of up to 6" of compression or extension, or 3" of compression and 3" of extension. The System has Class I, II, and III cycling capabilities. The System is classified and listed for use with U-400 series walls. The listings are good for both roof and floor assemblies.

UL listings for joints of 1" compression and/or extension (or up to 2" deflection only)*

HW-D-0060 Standard wall Perpendicular and parallel against steel and concrete decks 1 to 3 hour ratings
HW-D-0061 Cavity wall Perpendicular and parallel against steel and concrete decks 1 to 3 hour ratings
HW-D-0117 Standard and Cavity walls Perpendicular to metal decks with flute filled with cementious fireproofing 1 and 2 hour ratings
HW-D-0118 Standard and Cavity walls Perpendicular to metal decks with flute filled with fire caulk or fire spray 1 and 2 hour ratings
HW-D-0119 Shaft wall Perpendicular and parallel against steel and concrete decks 1 to 3 hour ratings
HW-D-0120 Shaft wall Perpendicular and parallel against steel and concrete decks 1 to 3 hour ratings

U.L Listings for joints of 3" of compression and/or extension (or up to 6" of deflection only).*

HW-D-1011 Standard wall Perpendicular and parallel against steel and concrete decks 1 to 3 hour ratings
HW-D-1012 Cavity wall Perpendicular and parallel against steel and concrete decks 1 to 3 hour ratings
HW-D-1019 Standard and Cavity walls Perpendicular to metal decks with flute filled with cementious fireproofing 1 and 2 hour ratings
HW-D-1020 Standard and Cavity walls Perpendicular to metal decks with flute filled with fire caulk or fire spray 1 and 2 hour ratings

*Tracks can be configured to any deflection between 1" to 6".

Please download for reference our Comparison of UL HW-D Listings by Movement table that lists maximum movement for every HW-D listing in the 2004 U.L. Fire Resistance – Volume 2A Directory.

Understanding Nominal Joint Width (Installed Width)
And Actual Movement in U.L. Listings

Nominal Joint Width in U.L. listings refers to installed width. Nominal Joint width does not equal movement capability because the joint material can only move a percentage of its thickness. For example, systems that require fire caulk or spray can only move a percentage of their nominal joint width because they are limited by compressibility, elasticity or bond strength. To determine actual movement you must multiply nominal joint width by the percentage of compression and/or extension.

For illustration: A 1” nominal joint width with 25% compression has an actual deflection capability of only 1/4”.

The Fire Trak System, when installed at a nominal joint width of 1”, has a full 100% movement in compression for a full 1” of deflection. By extension of track depth, the Fire Trak System can move 1” (100%) in both compression and extension for a combined range of movement of 2”.

The Fire Trak System is U.L. tested and listed at 1” and 3” nominal joint widths with 100% movement in both compression and extension for combined ranges of movement of 2” and 6”. The Fire Trak System can have any range of movement from 1” to 6” in 1/2” increments.